Impact Deformation and Dislocation Substructure of Ti-6al-7nb Biomedical Alloy
Author Name
Woei-Shyan Lee, Chia-Wei Chen
Affilition
University Road, Department of Mechanical Engineering, National Cheng Kung University, Tainan 701, Taiwan
Pages
42-46
Abstract
The high temperature deformation and dislocation substructure of Ti-6Al-7Nb biomedical alloy are investigated under high strain rate loading conditions using a split-Hopkinson pressure bar. Impact tests are performed at strain rates ranging from 1x103s-1 to 3x103s-1 and temperatures of 300℃and 700℃, respectively. The experimental results show that the flow stress, work hardening coefficient and strain rate sensitivity all increase with increasing strain rate, but decrease with increasing temperature. Transmission electron microscopy observations reveal that the dislocation density increases with increasing strain rate, but decreases with increasing temperature. A pronounced thermal softening effect is observed in the specimens deformed at 700℃ due to the rapid annihilation of the dislocations. However, a work hardening effect occurs at higher strain rates and lower temperatures due to an enhanced degree of dislocation multiplication and tangling. Finally, a linear relationship is observed between the square root of the dislocation density and the flow stress. Keywords - Split-Hopkinson Pressure Bar, Ti-6Al-7Nb Biomedical Alloy, Impact, Strain Rate, Dislocation.
  View Paper